Core Medical Imaging - Advanced Technology - Dedicated Service - Proven Solutions - From The Core Of the Northwest - 1.800.809.XRAY - 425.485.4330
Home . Products . Static DR . Canon CXDI-50RF

Canon CXDI-50RF

Canon CXDI-50RF

Portable R&F Flat-Panel Detector

Optimized for Multi-Purpose Use

The CXDI-50RF is equipped with a 14 x 17 inch large image receptor area and is capable of both radiography and fluoroscopy. This unit is suitable for a multi-purpose room; for example, a room dedicated to fluoroscopy in the morning and general radiography in the afternoon. The sensor unit can be used for table top radiography due to its portability. Taking advantage of its detachable cable, the sensor unit can be used in multiple rooms or multiple locations within the same room.

Up to 30 fps Fluoroscopic Imaging

The CXDI-50RF can take up to 30 frames per second fluoro. Multi-frame radiographic imaging up to 15 fps is also possible. The frame rate differs depending on the image capture mode and size. For fluoroscopy, the sensor unit is to be used in a docking station (similar to a cassette tray) which is equipped with an active air cooling system. 

Dynamic/Static Imaging Control Software

The control software can acquire and display both radiographic and fluoroscopic images easily and smoothly. The same software can display high resolution images and provides advanced image processing and all standard DICOM functions. X-ray controls from the generator can be ported into the control software as well.

System Configuration Example



Dimensions


CXDI-50RF Specification

Application  General radiography and fluoroscopy
Technology Flat panel detector: scintillator& amorphous silicon (a-Si)  
Sensor LANMIT (Large Area New-MIS sensor and TFT)
Scintillator Cesium Iodide (CsI: TI)
Pixel Pitch 160 x 160 microns
Pixels 2,208 x 2,688 pixels (approx. 5.9 million pixels) 
Image Size Automatic sizing up to 14 x 17 in. (35 x 43 cm)
Binning Mode 1 x 1, 2 x 2
Acquisition Mode Up to 30 fps 
Cooling Active air cooling
A/D Conversion 14-bit
Grayscale 4096 grayscales (12-bit)
 Preview image access time Approx. 2-4 seconds after x-ray exposure (for radiography)
 DICOM 3.0 Services Storage, Print Management, Modality Worklist, Performed Procedure Steps (MPPS), C-echo, and Storage Commitment –all as SCU
 Power (Voltage/Frequency) AC 100-240 V 50/60 Hz
Operating environment Sensor unit : 41-95 F(5-35 ?), 30 -75% RH (non-condensing)
Dimensions Sensor unit (W x L x T): 19.4 x 19.8 x 1.0 in. (493 x 503 x 26 mm)
Weight Sensor unit w/o cable: 12.5 lbs. (5.7 kg)
Standard components Sensor unit, sensor cable, power box
Certification UL 60601-1, IEC 60601-1-2, FDA 510(k)