Portable R&F Flat-Panel Detector
Optimized for Multi-Purpose Use
The CXDI-50RF is equipped with a 14 x 17 inch large image receptor area and is capable of both radiography and fluoroscopy. This unit is suitable for a multi-purpose room; for example, a room dedicated to fluoroscopy in the morning and general radiography in the afternoon. The sensor unit can be used for table top radiography due to its portability. Taking advantage of its detachable cable, the sensor unit can be used in multiple rooms or multiple locations within the same room.
Up to 30 fps Fluoroscopic Imaging
The CXDI-50RF can take up to 30 frames per second fluoro. Multi-frame radiographic imaging up to 15 fps is also possible. The frame rate differs depending on the image capture mode and size. For fluoroscopy, the sensor unit is to be used in a docking station (similar to a cassette tray) which is equipped with an active air cooling system.
Dynamic/Static Imaging Control Software
The control software can acquire and display both radiographic and fluoroscopic images easily and smoothly. The same software can display high resolution images and provides advanced image processing and all standard DICOM functions. X-ray controls from the generator can be ported into the control software as well.
System Configuration Example


Dimensions

CXDI-50RF Specification
| Application |
General radiography and fluoroscopy |
| Technology |
Flat panel detector: scintillator& amorphous silicon (a-Si) |
| Sensor |
LANMIT (Large Area New-MIS sensor and TFT) |
| Scintillator |
Cesium Iodide (CsI: TI) |
| Pixel Pitch |
160 x 160 microns |
| Pixels |
2,208 x 2,688 pixels (approx. 5.9 million pixels) |
| Image Size |
Automatic sizing up to 14 x 17 in. (35 x 43 cm) |
| Binning Mode |
1 x 1, 2 x 2 |
| Acquisition Mode |
Up to 30 fps |
| Cooling |
Active air cooling |
| A/D Conversion |
14-bit |
| Grayscale |
4096 grayscales (12-bit) |
| Preview image access time |
Approx. 2-4 seconds after x-ray exposure (for radiography) |
| DICOM 3.0 Services |
Storage, Print Management, Modality Worklist, Performed Procedure Steps (MPPS), C-echo, and Storage Commitment –all as SCU |
| Power (Voltage/Frequency) |
AC 100-240 V 50/60 Hz |
| Operating environment |
Sensor unit : 41-95 F(5-35 ?), 30 -75% RH (non-condensing) |
| Dimensions |
Sensor unit (W x L x T): 19.4 x 19.8 x 1.0 in. (493 x 503 x 26 mm) |
| Weight |
Sensor unit w/o cable: 12.5 lbs. (5.7 kg) |
| Standard components |
Sensor unit, sensor cable, power box |
| Certification |
UL 60601-1, IEC 60601-1-2, FDA 510(k) |